General Alarm Push Button:
• Remotely activates the general alarm to all speaker zones.
• The GA button is protected by a hinged cover, to prevent accidental operation of the General Alarm.
• Up to two PA-GAP panels can be connected to the DT-120/240 system, and both can be operated simultaneously.
• GA lamp can be adjusted via the dimmer.
Priority Microphone (inc. Hand Microphone):
• Pressing the PTT switch on the Hand Microphone enables ALL speaker zones on the PA Amplifier.
• While talking into Priority Microphone all other PA audio inputs are muted.
• For dual PA-GAP panel installations, Panel #1 will take priority over panel #2.
• Only the Decktalk supplied Hand-microphone should be used with the PA-GAP panel.
Dimmer:
• Adjusts the brightness of the General Alarm push button lamp (while GA is activated)
• Turn clockwise to increases brightness, and anti-clockwise to decrease.
Termination Hardware:
• Fitted with 6 industrial type \u0091push-in\u0092 terminals.
• Ensure care is taken not to damage panel while mounting & terminating.
• 6 Core 0.75mm2 Screen cable (Yard supplied) is required to connect to the DT 120/240.